Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 14(1)2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38201410

RESUMO

The aim of this study was to compare the effectiveness of trabeculectomy (TE) and deep sclerectomy (DS) in lowering intraocular pressure (IOP) and thereby preserving visual field and peripapillary retinal nerve fiber layer (RNFL) tissue in primary open-angle glaucoma (POAG) cases. IOP, number of IOP-lowering medications, visual acuity, mean defect of standard automated perimetry, and mean peripapillary RNFL thickness were retrospectively collected and followed up for 3 years after surgery. TE was performed in 104 eyes and DS in 183 eyes. Age, gender, laterality, IOP, number of medications, visual acuity, perimetry mean defect, and peripapillary RNFL thickness were equally distributed at baseline. Mean IOP decreased from 23.8 ± 1.4 mmHg and 23.1 ± 0.4 mmHg to 13.4 ± 0.6 mmHg (p < 0.001) and 15.4 ± 0.7 mmHg (p = 0.001) in the TE and DS groups, respectively. Mean defect remained stable (TE: -11.5 ± 0.9 dB to -12.0 ± 1.1 (p = 0.090); DS: -10.5 ± 0.9 dB to -11.0 ± 1.0 dB (p = 0.302)), while mean peripapillary RNFL thickness showed further deterioration during follow-up (TE group: 64.4 ± 2.1 µm to 59.7 ± 3.5 µm (p < 0.001); DS group: 64.9 ± 1.9 µm to 58.4 ± 2.1 µm (p < 0.001)). Both TE and DS were comparably effective concerning postoperative reduction in IOP and medication. However, glaucoma disease further progressed during follow-up.

2.
Eye Vis (Lond) ; 10(1): 50, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-38124210

RESUMO

BACKGROUND: To compare the intermediate-term efficacy of PRESERFLO (PF) MicroShunt implantation with trabeculectomy (TE) in patients with primary open-angle glaucoma, focusing on longitudinal changes of functional and structural parameters. METHODS: This retrospective comparative study included 104 eyes of 104 patients who underwent TE and 83 eyes of 83 patients that underwent PF implantation between January 2019 and December 2020, with a minimum follow-up of two years. Baseline and postoperative intraocular pressure (IOP), number of IOP-lowering medications, visual field mean defect (MD) and peripapillary retinal nerve fibre layer (RNFL) thickness measured using optical coherence tomography were assessed and compared between groups. RESULTS: Baseline characteristics (age, sex, IOP, number of IOP-lowering medications, MD, RNFL thickness) were comparable between the two groups (all P > 0.05). During the two-year of follow-up, mean IOP decreased from 24.09 ± 1.15 mmHg and 21.67 ± 0.77 mmHg to 11.37 ± 1.13 mmHg (P < 0.001) and 15.50 ± 1.54 mmHg (P = 0.028), and the mean number of IOP-lowering medications decreased from 3.25 ± 0.14 and 3.51 ± 0.14 to 0.53 ± 0.14 (P < 0.001) and 1.06 ± 0.43 (P < 0.001) in the TE and PF groups, respectively. MD remained stable [- 11.54 ± 0.93 dB and - 11.17 ± 1.66 to - 10.67 ± 0.91 dB (P = 0.226) and - 10.40 ± 4.75 dB (P = 0.628) in the TE and PF groups, respectively] but RNFL thickness decreased continuously during follow-up [62.79 ± 1.94 µm and 62.62 ± 2.05 µm to 57.41 ± 1.81 µm (P < 0.001) and 60.22 ± 1.98 µm (P = 0.182) in the TE and PF groups, respectively]. CONCLUSION: PF implantation is comparably effective in the intermediate term in lowering IOP and reducing the use of IOP-lowering medications over a two-year follow-up period. Although visual field defects were stable, RNFL continued to decrease during postoperative follow-up.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...